Search:
 
   Products






News News
Introducing New Grip-Lok for Suture-Free Securement of Popular Arrow® CVC and PICC Hubs
New Grip-Lok for Suture-Free Securement of the BD® Arterial Cannula with FloSwitch®
Introducing Grip-Lok Foley Catheter

More News


Information Information
About Zefon
Contact Us
Where to Buy
Literature Download
Sitemap
Product Demonstration Videos



Zefon International :: Gas Sampling Lines :: Anesthetic Gas Sampling lines

Anesthetic Gas Sampling lines  
Printable version
Anesthetic Gas Sampling lines 

 

Gas sampling lines used to monitor anesthetic gases.

  • Economical
  • Disposable, Single Patient Use
  • Non-Sterile
  • 100% Flow tested
  • Co-extruded PE/PVC tubing suitable for use with anesthestic gases
  • Filters and Nafion® Dryer attachment options

Line Selection Options

  • Connectors
    Most systems use a male/male luer-lock configuration for connecting the line to the anesthesia system and monitor. Anesthesia circuits use a female luer lock (on the wye, elbow or filter) which requires a male luer lock fitting on the gas line. The other end of the line depends on the manufacturer of the monitor, but many require a male fitting as well. The connector specification is not dependent on other accessories (Nafion ® tubing, filters) which may be included with the lines.


  • Length
    The length is dependent on the distance from the point of attachment (anesthesia circuit) to the monitor. Most lines are specified as 8 or 10 feet long.


  • Tubing Materials
    Zefon anesthetic gas sampling lines are manufactured from a co-extrusion of Polyethylene (PE) and PVC where the PE forms an inner layer and the PVC comprises the outer layer. This is very important when monitoring anesthetic gases becuase of the strong dissolvents present in anesthetic gases. PVC does not resist chemicals well and use of a standard PVC tube may cause plasticizers to deteriorate and result in inaccurate monitor readings. Polyethylene (PE) is natually resistent to many chemicals and by using a co-extruded tube with PE on the inner layer the most accurate results are assured.

    Note: Many monitor manufacturers will specify recommended sampling line specification in the monitor manual


  • Inner Diameter (ID) Size
    The ID of the tube is critical to the accuracy of the monitor. The correct ID to use is specified by the manufacturer of the monitor. The most common sizes used for anesthetic gases is .040" or .047" ID. Both sizes are stocked by Zefon.


  • Nafion® Dryer Attachments
    Many anesthetic gas monitoring systems require filtration of the air sample and drying of the air sample. Moisture from the air sample interferes with some methods of anesthetic gas analysis, and moisture can also destroy some of the detectors. Nafion® dryer tubing has the unique property of removing moisture from the air sample which is passing through the gas line, without affecting the gas concentration. Most monitor manufacturers will specify whether to use Nafion® or not.


  • Filter Attachments
    Filters which are included with the gas sampling line serve two functions. Because the filter absorbs water, moisture removal is attained. The filters have a pore size of 5.0µ and effectively prevents particulates from entering anesthitic gas monitors. Some systems will call for both a filter and Nafion ® dryer tube.

 

Download Zefon Gas Sampling Line Brochure

 

Ordering Information

8' PE/PVC Monitoring Lines
Product # Tube ID Connectors
ZML-9350 .040" Male/Male
ZML-9450 .040" Male/Female
ZML-9340 .047" Male/Male
ZML-9440 .047" Male/Female
10' PE/PVC Monitoring Lines
Product # Tube ID Connectors
ZML-9550 .040" Male/Male
ZML-9650 .040" Male/Female
ZML-9540 .047" Male/Male
ZML-9640 .047" Male/Female
All Zefon Gas Sampling Lines come individually packaged with 50 units per case

Attachments may be preinstalled on any line. To order, select the option you want and adjust the product number to reflect the option. To do this, simply replace the last digit of the product number. Example: To add option #3 to a ZML-9520, change the number to ZML-9523.

Option #1 - Add a 5.0um filter
Option #3 - Add a 12" Nafion® dryer segment
Option #6 - Add both a 5.0um filter and a 12" Nafion® dryer segment

Nafion is a registered trademark of Dupont


 

All Zefon medical products are sold exclusively through specialty distributors.
Product availability may vary by country/region. Please contact your local Zefon distributor for product, pricing and availability information in your area. A list of distributors can be found in the Where to Buy section on this website.
 

 

 
Copyright © 2003-2010 Zefon International
An ISO 9001-2008 and ISO 13485-2003 Certified Company