TSI Primary Flow Pump Calibrators  
TSI Primary Flow Pump Calibrators 
Printable version

The TSI 4146 and 4046 Primary Calibrators are portable, battery-operated units that are lightweight, easy to use and accurate within 2% of reading. Volumetric flow rate. is displayed continuously so adjustments to pump flow can be made in real-time.

  • Provides continuous real-time volumetric flow rate readings, so pump adjustment and calibration is fast and easy
  • Battery powered, compact and lightweight
  • Field portable—use the same primary calibrator for adjustment, calibration and periodic flow checks
  • 2 Flow ranges to select from:
        Model 4146 - 0.01-20 lpm
        Model 4046 - 2.5-300 lpm
        Model 4046 - 2.5-300 lpm with all connection required to use with Zefon Bio-Pump
  • Comes with a NIST traceable calibration certificate
  • Kits come complete and are ready to use

Personal sampling pumps must be calibrated before and after each use and routinely checked during use. Flow calibrators are used to adjust and measure the flow rate. of air sampling instruments.

Why is the adjustment and calibration of air sampling instruments necessary? Instruments that sample air must be flow adjusted, calibrated and routinely checked to ensure the accuracy of flow rate. The frequency of flow adjustment and/or calibration depends on the use, care and handling of the air sampling instruments and the regulations they are complying with. Determining exposure to various physical, chemical, radiological and biological substances is based on the accuracy of the total volume of air sampled and the sample duration.


Flow Measurement Range
Model 4146
Model 4046
0.01 to 20 lpm
2.5 to 300 lpm
Model 4146
Model 4046
±2% or 0.005 std. lpm, whichever is greater
±2% or 0.05 std. lpm, whichever is greater
Model 4146
Model 4046
5 in. × 2 in. × 1.25 in.
7.2 in. × 2.5 in. × 2.1 in.
Model 4146
Model 4046
2.2 lbs
3 lbs
Warm Up Time 1 Minute
DC Power Input 7.5 VDC ±1.5 V, 300 mA max

Each TSI Primary Flow calibrator is shipped complete with the following:

  • Calibrator
  • Battery pack including 6-AA size alkaline batteries
  • Tubing kit
  • Carry case
  • NIST traceable calibration certificate
  • User guide
  • Tubing and connectors for Zefon Bio-Pump (ZBP-200-CAL only)
Price varies by model selected. Please select a model below for exact price.

Additional Information Available

1. Download Product Data Sheet
2. Users Manual for TSI 4146 and 4046 Primary Calibrator

Manufacturer TSI
U/M Each
Stock Status Normally Ships within 24 hours

Product Price Order

  TSI 4146 with a flow range of 0.01-20 lpm
  Product #: TSI-4146


  TSI 4046 with Bio-Pump Plus Connections
  Product #: ZBP-200-CAL


Add to cart
All products and prices posted are valid for sale in the USA only
If you are not from the USA, CLICK HERE to locate
an Authorized Zefon Distributor in your area.

Accessories & Related Products  

Zefon Bio-Pump® Plus

Copyright © 2003-2016 Zefon International, Inc.
An ISO 9001-2008 Certified Company