Search
Filters
Close
Item Number: AT-N546

ORGANIC VAPOR, HIGH CAPACITY BADGE, 10BX

546 High Capacity Organic Vapor Badge, 10/Bx

Associated Analytical Methods: OSHA 7, NIOSH 1500, NIOSH 1550, NIOSH 1604
Item Number: AT-N546
Availability: Drop Ship From Manufacturer

Assay Technology’s 546 High Capacity Organic Vapor Badge is excellent for all-day monitoring of organic vapors that have high PELs (greater than 200 ppm). The 19-hole sampling face greatly reduces the possibility that the collection media becomes saturated, making a second wafer inside the badge unnecessary in most environments. While the 8-hour reporting limits are different for each chemical, they are generally around 0.5 ppm, which is well below most PELs. For specific information about your chemical of interest, check our Sampling Guide. The 546 badge is not usually recommended for STEL (15-minute) monitoring.

This badge is NON-RETURNABLE

Assay Technology also manufactures two other Organic Vapor Monitors, our 566 and 525 badge. For assistance in choosing which is best for your situation, use our guide.

Please note: The 546 monitor can NOT be used for acetic acid monitoring. See our 543 Acetic Acid Monitor.

Industrial Hygiene Labs:

  • Sampling rates are listed in our Sampling Guide or Requested Sampling Rates page (search by CAS #). Contact us if you can’t find a rate you need.
  • Opening the ChemDisk is made much easier using the pick we specify.
  • Media is available for QC testing. Use our M products (e.g. M566).
  • The media inside the 546 and 566 badges is the same. The only difference between the two badges is the sampling grid.

This badge collects the following:

  • Acetone
  • n-Butyl Acetate
  • t-Butyl Acetate
  • Chlorobromomethane
  • Cyclohexane
  • Dichlorodifluoromethane
  • 1,2-Dichloroethylene
  • Dichlorotetrafluoroethane
  • Ethyl Acetate
  • Ethanol
  • Ethyl Chloride
  • Ethyl Ether
  • n-Heptane
  • Isobutyl Acetate
  • Isopropyl Acetate
  • Isopropyl Alcohol
  • Isopropyl Ether

Store at room temperature before and after use. Refrigerated storage is always OK.

It is recommended that the badge be returned to the lab within 14 days of use.

Use for:

8-hour TWA for chemicals with a PEL 200 ppm or greater.

For STEL monitoring, always use a 566 or 525 badge.

Assay Technology’s 546 High Capacity Organic Vapor Badge is excellent for all-day monitoring of organic vapors that have high PELs (greater than 200 ppm). The 19-hole sampling face greatly reduces the possibility that the collection media becomes saturated, making a second wafer inside the badge unnecessary in most environments. While the 8-hour reporting limits are different for each chemical, they are generally around 0.5 ppm, which is well below most PELs. For specific information about your chemical of interest, check our Sampling Guide. The 546 badge is not usually recommended for STEL (15-minute) monitoring.

This badge is NON-RETURNABLE

Assay Technology also manufactures two other Organic Vapor Monitors, our 566 and 525 badge. For assistance in choosing which is best for your situation, use our guide.

Please note: The 546 monitor can NOT be used for acetic acid monitoring. See our 543 Acetic Acid Monitor.

Industrial Hygiene Labs:

  • Sampling rates are listed in our Sampling Guide or Requested Sampling Rates page (search by CAS #). Contact us if you can’t find a rate you need.
  • Opening the ChemDisk is made much easier using the pick we specify.
  • Media is available for QC testing. Use our M products (e.g. M566).
  • The media inside the 546 and 566 badges is the same. The only difference between the two badges is the sampling grid.

This badge collects the following:

  • Acetone
  • n-Butyl Acetate
  • t-Butyl Acetate
  • Chlorobromomethane
  • Cyclohexane
  • Dichlorodifluoromethane
  • 1,2-Dichloroethylene
  • Dichlorotetrafluoroethane
  • Ethyl Acetate
  • Ethanol
  • Ethyl Chloride
  • Ethyl Ether
  • n-Heptane
  • Isobutyl Acetate
  • Isopropyl Acetate
  • Isopropyl Alcohol
  • Isopropyl Ether

Store at room temperature before and after use. Refrigerated storage is always OK.

It is recommended that the badge be returned to the lab within 14 days of use.

Use for:

8-hour TWA for chemicals with a PEL 200 ppm or greater.

For STEL monitoring, always use a 566 or 525 badge.


Cross-reference of Assay Monitors with 3M Monitors

 Assay Monitors  3M Monitors
 AT-N555  3M-3551
 AT-N566  3M-3500
 AT-N566  3M-3520
 AT-N571  3M-3721

*The above table of cross-referenced product information is for comparison purposes only. The information about non-Zefon products was gathered from published price lists, websites and catalogs of other manufacturers and providers, which information may change from time to time. Any Trademarks listed are owned by their respective owner. No ownership is implied. Please note packaging quantities between manufacturers may vary.

 Item  Before Sampling  After Sampling
 AT-N525, AT-N543, AT-N546, AT-N566  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N549  Store and Ship at Room Temperature  Store and Ship at Room Temperature

 Return to Lab within 14 days
 AT-N555  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N571  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N574  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days
 AT-N575  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days. (Lot 3C20 and after)
 AT-N581  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N584  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N585  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 28 days
 AT-N586  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N587  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days 
 AT-N592  Ship at Room Temperature to arrive within 2 calendar days. Store under refrigerated conditions for maximum shelf life.  Room Temperature

 Return to Lab within 14 days
 AT-N593  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N594  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 28 days
 AT-N595  Store and Ship at Room Temperature  Store and Ship under Refrigeration

 Return to Lab within 3 days
 AT-N596  Store and Ship at Room Temperature  Room Temperature

 Return to Lab within 14 days

Technical Documents

 Product  Technical Documents
 AT-N525
 AT-N543
 AT-N546
 AT-N555
 AT-N566
 AT-N571
 AT-N575
 AT-N581
 AT-N584
 AT-N585
 AT-N586
 AT-N592
 AT-N593
 AT-N594

 

Products specifications
MANUFACTURER Assay Technology
TYPE Organic Vapor
Products specifications
MANUFACTURER Assay Technology
TYPE Organic Vapor
Categories